{"id":1351,"date":"2024-04-02T15:37:20","date_gmt":"2024-04-02T13:37:20","guid":{"rendered":"https:\/\/support.plugandtrack.com\/kb\/verifier-calculs-calibrage\/"},"modified":"2026-04-16T09:45:35","modified_gmt":"2026-04-16T07:45:35","slug":"validate-calibration-caluclations","status":"publish","type":"ht_kb","link":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/","title":{"rendered":"How do I check calibration calculations?"},"content":{"rendered":"<p>To validate the calibration calculations made in Thermotrack-Webserve, you can proceed as follows:<\/p>\n<ol>\n<li>Download the Excel file https:\/\/thermobouton.fr\/ftp\/plugandtrack\/Thermotrack-Webserve\/Correction%20Valeurs%20TTW.xlsm<br \/>\nThe file contains macros. Make sure you are authorised to use macros on your computer.<\/li>\n<li>Select a calibrated sensor in Thermotrack-Webserve<\/li>\n<li>Locate the sensor by its serial number on its Sensor Net Connect or FoxNet Controller<br \/>\n(search for the device using the Microchip Ethernet Discoverer https:\/\/thermobouton.fr\/ftp\/plugandtrack\/Thermotrack-Webserve\/Microchip%20Ethernet%20Discoverer.exe)<\/li>\n<li>Select the sensor<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1346\" src=\"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC.png\" alt=\"\" width=\"1465\" height=\"783\" srcset=\"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC.png 1465w, https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC-300x160.png 300w, https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC-1024x547.png 1024w, https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC-768x410.png 768w, https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC-50x27.png 50w, https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC-60x32.png 60w, https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC-100x53.png 100w\" sizes=\"auto, (max-width: 1465px) 100vw, 1465px\" \/><\/li>\n<li>Choose\n<ul>\n<li>Duration: 15 minutes (or more if required)<\/li>\n<li>Value : Temperature<\/li>\n<\/ul>\n<\/li>\n<li>Leave the screen open for 15 minutes (Do not close the screen)<\/li>\n<li>Press &#8220;Download&#8221; and save the file in CSV format<\/li>\n<li>In the Excel file, select the tab corresponding to the calibration method used in Thermotrack-Webserve (Linear or Quadratic).<\/li>\n<li>Copy the dates, times and values from the CSV into column A, B and C &#8220;Values&#8221; of the Excel file.<\/li>\n<li>In Thermotrack-Webserve, select the probe and export the values to Excel<\/li>\n<li>Now check that the values in column D &#8220;Corrected values&#8221; match.<br \/>\nPlease ensure that the times of the values match.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>To validate the calibration calculations made in Thermotrack-Webserve, you can proceed as follows: Download the Excel file https:\/\/thermobouton.fr\/ftp\/plugandtrack\/Thermotrack-Webserve\/Correction%20Valeurs%20TTW.xlsm The file contains macros. Make sure you are authorised to use macros on your computer. Select a calibrated sensor in Thermotrack-Webserve Locate the sensor by its serial number on its Sensor Net&#8230;<\/p>\n","protected":false},"author":1,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"footnotes":""},"ht-kb-category":[62],"ht-kb-tag":[],"class_list":["post-1351","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-tech-notes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How do I check calibration calculations? Support Plug and Track<\/title>\n<meta name=\"description\" content=\"How do I check calibration calculations? Support Plug and Track\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How do I check calibration calculations?\" \/>\n<meta property=\"og:description\" content=\"How do I check calibration calculations? Support Plug and Track\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/\" \/>\n<meta property=\"og:site_name\" content=\"Support Plug and Track\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-16T07:45:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1465\" \/>\n\t<meta property=\"og:image:height\" content=\"783\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/\",\"url\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/\",\"name\":\"How do I check calibration calculations? Support Plug and Track\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/support.plugandtrack.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Courbe-SNC.png\",\"datePublished\":\"2024-04-02T13:37:20+00:00\",\"dateModified\":\"2026-04-16T07:45:35+00:00\",\"description\":\"How do I check calibration calculations? Support Plug and Track\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/#primaryimage\",\"url\":\"https:\\\/\\\/support.plugandtrack.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Courbe-SNC.png\",\"contentUrl\":\"https:\\\/\\\/support.plugandtrack.com\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/Courbe-SNC.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/thermotrack-webserve-en\\\/tech-notes\\\/validate-calibration-caluclations\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How do I check calibration calculations?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/\",\"name\":\"Support Plug and Track\",\"description\":\"All answers to your questions about our products\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/#organization\"},\"alternateName\":\"Comment installer et utiliser les logiciels Thermotrack\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/#organization\",\"name\":\"Support Plug and Track by Proges Plus\",\"url\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/support.plugandtrack.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/logo-plugandtrack.png\",\"contentUrl\":\"https:\\\/\\\/support.plugandtrack.com\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/logo-plugandtrack.png\",\"width\":225,\"height\":225,\"caption\":\"Support Plug and Track by Proges Plus\"},\"image\":{\"@id\":\"https:\\\/\\\/support.plugandtrack.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/showcase\\\/plug-and-track\\\/\"],\"description\":\"PLUG AND TRACK\",\"email\":\"support@thermotrack.com\",\"telephone\":\"+33320646363\",\"legalName\":\"PROGES PLUS\",\"foundingDate\":\"1985-09-01\",\"vatID\":\"FR53333601573\",\"taxID\":\"FR53333601573\",\"duns\":\"380299917\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"11\",\"maxValue\":\"50\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How do I check calibration calculations? Support Plug and Track","description":"How do I check calibration calculations? Support Plug and Track","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/","og_locale":"en_US","og_type":"article","og_title":"How do I check calibration calculations?","og_description":"How do I check calibration calculations? Support Plug and Track","og_url":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/","og_site_name":"Support Plug and Track","article_modified_time":"2026-04-16T07:45:35+00:00","og_image":[{"width":1465,"height":783,"url":"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/","url":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/","name":"How do I check calibration calculations? Support Plug and Track","isPartOf":{"@id":"https:\/\/support.plugandtrack.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/#primaryimage"},"image":{"@id":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/#primaryimage"},"thumbnailUrl":"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC.png","datePublished":"2024-04-02T13:37:20+00:00","dateModified":"2026-04-16T07:45:35+00:00","description":"How do I check calibration calculations? Support Plug and Track","breadcrumb":{"@id":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/#primaryimage","url":"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC.png","contentUrl":"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2024\/04\/Courbe-SNC.png"},{"@type":"BreadcrumbList","@id":"https:\/\/support.plugandtrack.com\/en\/thermotrack-webserve-en\/tech-notes\/validate-calibration-caluclations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.plugandtrack.com\/en\/"},{"@type":"ListItem","position":2,"name":"How do I check calibration calculations?"}]},{"@type":"WebSite","@id":"https:\/\/support.plugandtrack.com\/en\/#website","url":"https:\/\/support.plugandtrack.com\/en\/","name":"Support Plug and Track","description":"All answers to your questions about our products","publisher":{"@id":"https:\/\/support.plugandtrack.com\/en\/#organization"},"alternateName":"Comment installer et utiliser les logiciels Thermotrack","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.plugandtrack.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/support.plugandtrack.com\/en\/#organization","name":"Support Plug and Track by Proges Plus","url":"https:\/\/support.plugandtrack.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/support.plugandtrack.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2023\/01\/logo-plugandtrack.png","contentUrl":"https:\/\/support.plugandtrack.com\/wp-content\/uploads\/2023\/01\/logo-plugandtrack.png","width":225,"height":225,"caption":"Support Plug and Track by Proges Plus"},"image":{"@id":"https:\/\/support.plugandtrack.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/showcase\/plug-and-track\/"],"description":"PLUG AND TRACK","email":"support@thermotrack.com","telephone":"+33320646363","legalName":"PROGES PLUS","foundingDate":"1985-09-01","vatID":"FR53333601573","taxID":"FR53333601573","duns":"380299917","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"11","maxValue":"50"}}]}},"_links":{"self":[{"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/ht-kb\/1351","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/comments?post=1351"}],"version-history":[{"count":0,"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/ht-kb\/1351\/revisions"}],"wp:attachment":[{"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/media?parent=1351"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=1351"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.plugandtrack.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=1351"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}